Glass-lined Equipment

We began to manufacture glass-lined equipment from the fifties, is one of earliest manufacture this kinds of products. At present, we not only manufacture various glass-lined reactor, storage tank, metric tank, distillation tank of 50L-20000L and pipe parts, but also manufacture various non-standard glass-lined equipment as customer’s request.

Glass-lined Equipment


Glass-lined Equipment


We win favorable comment of customer of home and abroad by advanced technology, good corrosion resistance, long life etc of glass-lined equipment. The products are sold well at home, they are also exported to more than twenty counties and region such as Japan, Korea, Indonesia, Pakistan, India, Spain, Argentina etc.

Corrosion Resistance of Glaze

Medium

Concentration%

Temperature?

Corrosion Rate mm/year

AlCl3

30

<105

<0.005

KAl(SO4)2

10--50

<105

<0.005

HCl

<35

<105

<0.005

Al2(SO4)3

20--50

<105

<0.005

HCl

>5

>105

0.02--0.05

NH4Cl

<50

<105

<0.005

HNO3

5--17

<105

<0.005

HCHO

~100

<105

<0.005

HNO3

100

<60

<0.005

K2SO4

10

<105

<0.005

H2SO4

<80

150

<0.005

NaCl

50

105

<0.005

H3PO4

40

100

0.02--0.05

C2H2O4

10

<38

<0.005

H3PO4

40

>150

>0.05

NaF

<5

<100

<0.005

H3PO4

30--80

<100

<0.005

NaHSO

20--50

100

<0.02

NaOH

<25

Constant tem.

<0.005

C2H4(NH2)OH

~100

<105

<0.005

NaOH

20

60

>0.02

C2H4(NH2)OH

~100

<200

<0.005

NaOH

20

80

>0.05

Br

100

<80

0.005--0.02

NaOH

30

<38

<0.005

CCl4

50--100

<80

<0.005

NaCO3

30

60

<0.03

H2CrO4

20--30

<105

<0.005

NaHCO3

>25

Constant tem.

<0.005

FeCl3

10--40

<105

0.02--0.05

NaHCO3

>25

100

<0.02

(HO3)C6H2COOH

100

<105

<0.005

CuSO4

10--50

<105

<0.005

COOH(CH2)2CH(NH2)

100

<100

<0.005

CuCl2

10--50

<105

<0.005

C6H6

100

<100

<0.005

Cu(NO3)2

10--50

<105

<0.005

C6H5OH

100

<100

<0.005

CH3COOH

~100

<100

<0.005

NaNO3

10--50

<100

<0.005

AlCl3

10

>200

>0.05

Note:Hydro fibroid acid, strong phosphoresced with high temperature and very strong sodium should be prohibited.

Na2SO4

20

<100

<0.005

 

Physically Mechanical Property

Name

Target

Check Standard

Test Plate

Sudden variation of temperature difference resistance(°C)

>200

GB7987--87

Mechanical impact resistance(J)

>200×10-3

GB7990--87

Requirements of equip.

Glass-lined thickness(mm)

0.8-2.0

GB7991--87

High voltage test(kV)

6(Rechecked by users)

GB7993--87

Pressure resistance(Mpa)

Inner<0.4Jacket<0.6

GB7994--87

Temperature in use(°C)

0-200

HG2432--93

Sadden variation of temperature difference resistance (°C)

Cooling impact110 Thermal impact120

GB7987--87

 



/ Centrifuge & Separator / Glass-lined Equipment / Packing machine / Spray Booth / Cycloid reducer /
/ Plastic Injection Moulding Machine and Die Casting Machine / Pharmaceutical Equipment /
/ Pharmaceutical and Chemical Materials / Handicraft /